The JA-107K is an advanced version of the JABLOTRON 100+ security system. It is designed for large living spaces, offices and businesses. It can only be installed by a trained technician with a valid Jablotron Alarms certificate.
Download technical specification
It also offers flexible protection solutions for residential complexes, administrative buildings and companies that require a multi-section system. The adjustments and sizing of the system are programmed through the F-Link software (from version 2.0.0).
The JA-107K control panel offers:
The control panel has:
The control panel also offers functions such as:
The following products with the control panel ARE NOT COMPATIBLE:
The following products with the control panel ARE COMPATIBLE under certain conditions:
Control panel power supply~ 110 – 230 V/50 – 60 Hz, max. 0.85 A with fuse F1.6 A/250 V, Protection class IIBack-up battery12 V; 7 to 18 Ah (lead gel)Maximum battery charging time48 hBUS voltage (red - black)12.0 to 13.8 VMaximum continuous current consumption from the control panel2000 mA permanent
3000 mA for 60 minutes
(max. 2000 mA for one BUS)Max. continuous current consumption for back-up 12 hoursWithout GSM communicatorLAN – OFF: 1135 mA
LAN – ON: 1107 mAWith GSM communicatorLAN – OFF: 1100 mA
LAN – ON: 1072 mAMax. continuous current consumption for back-up 24 hoursWithout GSM communicatorLAN – OFF: 535 mA
LAN – ON: 499 mAWith GSM communicator
LAN – OFF: 530 mA
LAN – ON: 494 mA
Maximum number of devices230LAN communicatorEthernet interface, 10/100BASEDimensions357 x 297 x 105 mmWeight with/without AKU7027 g/1809 gReaction to invalid code entryAlarm after 10 wrong code entriesEvent memoryApprox. 7 million latest events, including date and timePower supply unitType A according to EN 50131-6
T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC.GSM communicator (2G)850 / 900 / 1800 / 1900 MHzClassificationSecurity grade 2 according to EN 50131-1Operational environmentEnvironmental class II (indoor general) according to EN 50131-1Operational temperature range-10 °C to +40 °CAverage operational humidity75 % RH, non-condensingComplies withEN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10,
EN 50136-1, EN 50136-2, EN 50581Radio operating frequency (with the JA 11xR module)868.1 MHzRadio emissionsETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM)EMCEN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7Safety conformityEN 62368-1+A11Caller identification (CLIP)ETSI EN 300 089Operational conditionsERC REC 70-03Certification bodyTrezor Test s.r.o. (no. 3025)