Your shopping cart is empty!
The core element of the JABLOTRON 100+ security system. A control panel for protecting family houses, offices and smaller companies. It can only be installed by a trained technician with a valid Jablotron Alarms certificate.
Download technical specification
The required adjustments and sizing of the system are programmed through the F-Link software (from version 2.0.0).
The JA-103K control panel offers:
The control panel has:
The control panel also offers functions such as:
The following products with the control panel ARE NOT COMPATIBLE:
The following products with the control panel ARE COMPATIBLE under certain conditions:
Control panel power supply | ~ 110 – 230 V/50 – 60 Hz, max. 0.28 A with fuse F1.6 A/250 V, Protection class II |
||
---|---|---|---|
Back-up battery | 12 V; 2.6 Ah (lead gel) | ||
Maximum battery charging time | 48 h | ||
BUS voltage (red - black) | 12.0 to 13.8 V | ||
Maximum continuous current consumption from the control panel | 1000 mA | ||
Max. continuous current consumption for back-up 12 hours | Without GSM communicator | LAN – OFF: 115 mA LAN – ON: 88 mA |
|
With GSM communicator | LAN – OFF: 80 mA LAN – ON: 53 mA |
||
Max. continuous current consumption for back-up 24 hours | Without GSM communicator | LAN – OFF: 21 mA | |
With GSM communicator | LAN – OFF: 17 mA | ||
Maximum number of devices | 50 | ||
LAN communicator | Ethernet interface, 10/100BASE | ||
Dimensions | 268 x 225 x 83 mm | ||
Weight with/without AKU | 1844 g/970 g | ||
Reaction to invalid code entry | Alarm after 10 wrong code entries | ||
Event memory | Approx. 7 million latest events, including date and time | ||
Power supply unit | Type A according to EN 50131-6 T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC. |
||
GSM communicator (2G) | 850 / 900 / 1800 / 1900 MHz | ||
Classification | Security grade 2 according to EN 50131-1 | ||
Operational environment | Environmental class II (indoor general) according to EN 50131-1 | ||
Operational temperature range | -10 °C to +40 °C | ||
Average operational humidity | 75 % RH, non-condensing | ||
Complies with | EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581 | ||
Radio operating frequency (with the JA 11xR module) | 868.1 MHz | ||
Radio emissions | ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM) | ||
EMC | EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7 | ||
Safety conformity | EN 62368-1+A11 | ||
Caller identification (CLIP) | ETSI EN 300 089 | ||
Operational conditions | ERC REC 70-03 | ||
Certification body | Trezor Test s.r.o. (no. 3025) |